ETM2L PV On-Grid Circuit Breaker – Molded Case Type
The ETM2L Series PV On-Grid Low-Voltage Circuit Breaker (hereinafter referred to as the CircuitBreaker) is a low-voltage circuit breaker specifically designed for distributed PV power grid connection.Integrating an electric actuator, an intelligent controller, and a molded case circuit breaker, it’ sintended to protect circuits or electrical equipment from overcurrent, short circuit, open phase,undervoltage, voltage loss and more.The Circuit Breaker can achieve undervoltage delayed tripping and avoid voltage fluctuations andsudden drops in power systems, ensuring that the PV power supply does not immediately leave thegrid when there are voltage fluctuations, and maximizing the support role of distributed PV powersupply on the grid. At the same time, it can also enable users to achieve the maximum economic benefits.
Scope of Application
The ETM2L Series PV On-Grid Low-Voltage Circuit Breaker (hereinafter referred to as the CircuitBreaker) is a low-voltage circuit breaker specifically designed for distributed PV power grid connection.Integrating an electric actuator, an intelligent controller, and a molded case circuit breaker, it’ sintended to protect circuits or electrical equipment from overcurrent, short circuit, open phase,undervoltage, voltage loss and more.The Circuit Breaker can achieve undervoltage delayed tripping and avoid voltage fluctuations andsudden drops in power systems, ensuring that the PV power supply does not immediately leave thegrid when there are voltage fluctuations, and maximizing the support role of distributed PV powersupply on the grid. At the same time, it can also enable users to achieve the maximum economic benefits.
The Circuit Breaker is included with an electric actuator, which can achieve automatic closing onvoltage detected, effectively improving the automation performance of distributed PV distributionsystems. The Circuit Breaker is equipped with an RS485 serial interface, which can meet therequirements of communication networking.
Standard
GB 14048.2: Low-voltage switchgear and controlgear Part 2 Circuit-breakersQ/GDW 1972-2013: Technical specifications for low-voltage circuit-breakers for distributedgrid-connected PV stations
GB/T22710: Electronic controllers for low-voltage circuit breakers
GB/T 2423.1: Environmental testing for electric and electronic products Part 2: Testmethod – Tests A: Cold
GB/T 2423.2: Environmental testing for electric and electronic products – Part 2: Testmethod Tests B: Dry heat
Dimensions(mm)
| Model | Overall Dimensions | Installing Dimensions | |||
| L | W | T | W×L | ΦD | |
| 125AF | 220 | 122 | 138 | 60×200 | Φ4.5 |
| 250AF | 240 | 142 | 137 | 70×202 | Φ4.5 |
| 400AF | 337 | 198 | 186 | 96×274 | Φ8 |
| 630AF | 337 | 198 | 186 | 96×274 | Φ8 |
| 800AF | 370 | 280 | 190 | 140×333 | Φ8 |
Technical Parameters
| Item/Parameter Level/Spec |
ETM2L-125M/3N | ETM2L-250M/3N | ETM2L-400M/3N | ETM2L-630M/3N | ETM2L-800M/3N |
| Frame Current (A) | 125 | 250 | 400 | 630 | 800 |
| Number of Poles | 3P+N | ||||
| Rated Working Voltage Ue (V) | AC400 / 50HZ | ||||
| Rated Insulation Voltage Ui (V) | AC800 | ||||
| Rated Impulse Withstand Voltage Uimp | 8kW | ||||
| Flashover Distance (mm) | 50 | 50 | 100 | 100 | 100 |
| Limit Short Circuit Breaking Capacity Icu (kA) | 50 | 50 | 75 | 75 | 65 |
| Operating Short Circuit Breaking Capacity Ics (kA) | 35 | 35 | 50 | 50 | 42 |
| Use Category | B | A | B | B | B |
| Rated Short Time Withstand Current Icw (kA / 1s) | 5/1S | 5/1S | 10/1S | 10/1S | 10/1S |
| Automatic Closing Time (s) | 25~30 | ||||
| Overvoltage Protection Value (V) ※ | 253-300V, with delay adjustable | ||||
| Undervoltage Protection Value (V) ※ | 154-187, with a delay of 0-10 seconds, adjustable at one gear per second | ||||
| Total Number of Operations | 10000 | 8000 | 5000 | ||
| Trip on Power Outage ※ | A delay of 0-10 seconds, adjustable at one gear per second | ||||
| Restore Voltage ※ | 185-276V | ||||
| Overload Protection | ● | ● | ● | ● | ● |
| Short Circuit Protection | ● | ● | ● | ● | ● |
| Residual Current Protection | ● | ● | ● | ● | ● |
| Close on Voltage Detected | ● | ● | ● | ● | ● |
| Open Phase Protection | ● | ● | ● | ● | ● |
| Overvoltage/Undervoltage Protection | ● | ● | ● | ● | ● |