DZ47 Series Miniature Circuit Breaker

Applicable Standards

IEC 60898-1 GB/T 10963.1 GB/T16917.1

IEC 60947-2 GB/T 14048.2(DZ47-125)

Model and meaning

DZ47 63 1P C 63A OF+MN AC230V
Product name Frame grade Poles Trip Type Rated current Attachment Code Attachment voltage
DZ47 Series
Miniature Circuit
Breaker
63
125
1P
2P
3P
4P
C
D
(Customization
available upon
request: B)
1A、3A、6A、10A
16A、20A、25A
32A、40A、50A
63A、80A、100A、125A
OF Auxiliary Contacts SD Alarm Contacts
Note: Choose one of the two options
Mn Undervoltage MV Overvoltage
MN+MV Undervoltage/Overvoltage
MX+OF Shunt + Auxiliary
Note: MN+MV
Can only be installed with ET65-125-2P
circuit breakers;
24V DC
(Compatible with 24-48V DC)
230V AC
(Compatible with 110-130V DC/
230-400V AC)

Features

DZ47-63 Breaking Capacity:

Rated current (A) Type(Poles) Voltage (V) Breaking Capacity (A)
1 ~ 40 1P 230/400 6000/H Type 10000
1 ~ 40 2、3、4P 400 6000/H Type 10000
50 ~ 63 1P 230 6000/H Type 10000
50 ~ 63 2、3、4P 400 6000/H Type 10000

DZ47-63 Trip Unit Release Action Characteristics:

Trip Type Characteristics
Delay 1.13 In ≥ 1 hour without tripping
1.45 In < 1 h trip
2.55 In: 1–120 s trip (>32 A); 1–60 s (≤ 32A)
Instantly (Type C: 5In ≥ 0.1 s without tripping); (Type D: 10In ≥ 0.1 s without tripping)
(Type C: 10 In < 0.1 s trip); (Type D: 20 In < 0.1s trip)

DZ47-63 Protection Features:

Rated temperature for protective characteristics 30°C
Rated voltage AC 230V/400V
Rated current DZ47 (C): (1、2、3、4、5) 6、10、16、20、25、32、40、50、63A
DZ47(D): (1、2、3、4、5) 6、10、16、20、25、32、40、50、63A
Electrical life At least 6,000 times
Mechanical life At least 20,000 times
Damp-heat test Class 2 (95% relative humidity at 55° C)

The breaking capacity, rated operating voltage, and related rated short-circuit breaking capacity of the DZ47- 125 are as follows:

Rated current (A) Rated short-circuit breaking capacity
Type (Poles) Voltage (V) Expected current (A) for the test circuit Power factor
63, 80, 100, 125 1, 2, 3, 4 230/400 6000 0.45 ~ 0.50

DZ47-125 Overcurrent Tripping Characteristics:

Ambient air temperature I/In Test Duration and Expected Results I/In Test Duration and Expected Results Initial state
In ≤ 63A In > 63A In ≤ 100A(A)
40±2℃ 1.05 (C) No tripping within 1 hour No tripping within 2 hours 1.0 (D) >No tripping for 2 hours Cold start
1.30 (C) Trips within 1 hour Trips within 2 hours 1.2 (D) ≤ 2 hours: Trip Start in Hot Mode
-5 ~ 40℃ 5.0 ~ 10.0 (C) < 0.1 s trip Cold start
10.0 ~ 20.0 (D) < 0.1 s trip

Shape and size