ETM3E Series Intelligent Measurement Circuit Breaker

ETM3E series Intelligent Measurement Circuit Breaker
LCD display / Built-in communication functions/ High-precision metering / Real-time display ofthree-phase voltage and currentComplies with the technical requirements of StateGrid and China Southern Power Grid, and meetsthe requirements for residential distributionequipment in Jiangsu Province and Document501

Applicable Standards :IEC 60947-2 GB/T 14048.2

Model and meaning

3 3 10 100
Poles Name of the trip device Attachment Code Rated current
3P
4P
Electronic Attachment Code 16A~1250A
ETM3E 125 H P
Name Frame Grade Breaking Capacity Code Operation Mode Code
ETM3E Series intelligent
molded case circuit breaker
125
250
400
630
800
1250
M
H
Direct handle operation (no code)
P: Electric operation
Z: Rotary handle operation

Attachment Code

Attachment Name Alarm contact Shunt trip unit Shunt trip unit + Alarm contact Auxiliary contacts Auxiliary contacts + Alarm contacts Undervoltage trip device Undervoltage Trip Unit + Alarm Contact Shunt trip unit + Auxiliary contacts Shunt Trip Unit + Auxiliary Contacts + Alarm Contacts 2 sets auxiliary contacts Shunt Trip Unit + Undervoltage Trip Unit Shunt Trip Unit + Undervoltage Trip Unit + Alarm Contact
Attachment Code 08 10 18 20 28 30 38 40 48 60 70 78

Note: When the auxiliary contact and the alarm contact are on the same side, they form an auxiliary-alarm combination.

Main Technical Speciffcations

Model ETM3E-125 ETM3E-250 ETM3E-400 ETM3E-630 ETM3E-800 ETM3E-1250
Rated current Inn (A) 125 250 400 630 800 1250
Breaking Capacity Rating M H M H M H M H M H M H
Rating current Ir1 (A) 32(16,25,32)
63(32,40,50,63)
125(63,80,100,125)
250(100,125,140,160,180,
200,225,250)
400(200,225,250,315,
350,400)
630(400,500,630) 800(630,700,800) 1250(800,1000,1250)
Poles 3、4 3、4 3、4 3、4 3、4 3、4 3、4 3、4 3、4 3、4 3、4 3、4
Rated insulation voltage Ui (V) 800
Rated operating voltage Ue (V) 400
Rated impulse withstand voltage Uimp (kV) 8
Maximum short-circuit breaking capacity Icu (kA) 50 85 50 85 50 100 50 100 50 100 50 100
Short-circuit breaking capacity Ics (kA) 35 50 50 50 50 65 50 65 50 65 50 65
Rated short-time withstand current Icw (kA)/1 s 1.2 5 5 10 10 10
Category of Use A B B B B B
Arc length (mm) ≤ 50 ≤ 100
Operational Performance Powered (times) 7000
Not Powered(times) 10000
Dimensions (mm) Length L 150 165 257 270 280 406
Width W 92 107 150 180 210 210
Height H 108 110 151 155 159 193

 Shape and size

Reviews

There are no reviews yet.

Be the first to review “ETM3E Series Intelligent Measurement Circuit Breaker”

Your email address will not be published. Required fields are marked *