HGL(ETGL) series Load disconnector

The HGL (ETGL) series load isolating switches are primarily used in circuits with a frequency of 50 Hz, a rated voltage of 400 V and a rated current of up to 3,150 A. They are designed for infrequent switching of circuits and for the isolation of electrical equipment.

Scope of Application

The HGL (ETGL) series load isolating switches are primarily used in circuits with a frequency of 50 Hz, a rated voltage of 400 V and a rated current of up to 3,150 A. They are designed for infrequent switching of circuits and for the isolation of electrical equipment.

Product Overview

  • The spring-energised instantaneous release mechanism enables rapid make or break (13.8 metres per second), irrespective of the speed of the operating handle, thereby significantly enhancing arc-quenching capability
  • The casing, manufactured from glass fibre-reinforced unsaturated polyester resin, offers excellent flame-retardant properties, dielectric properties, carbonisation resistance and impact resistance.
  • The parallel double-break contacts feature a self-cleaning mechanism.
  • All contacts have two separate contact surfaces. The large isolation distance allows the handle to be secured with three locks simultaneously when in the ‘0’ position, reliably preventing accidental operation.

Normal operating and installation conditions

  • Ambient air temperature not exceeding +40°C and not falling below -5°C; relative humidity not exceeding 95 per cent
  • Altitude of the installation site not exceeding 2,000 metres
  • No explosive atmospheres
  • No exposure to rain or snow

Note: If the equipment is intended for use in conditions where the ambient air temperature exceeds +40°C or falls below -5°C, the user should inform the manufacturer.

HGL(ETGL)-63~3150A Load disconnector

  • The HGL (ETGL) series load switches are available in seven sizes ranging from 63 A to 3150 A. These are basic models with a modular design, available in three-pole and four-pole configurations (three-pole plus a neutral pole capable of being switched on and off), and are primarily used for closing and opening circuits or for electrical isolation; models with a rated current of 1000 A and above are suitable for electrical isolation only.
  • A marking window on the front panel indicates the contact make/break status.
  • A rear observation window can be provided on request to allow direct observation of the contact status; for window styles, refer to the HGL(ETGL)-160A-1600A/KH cabinet-mounted load isolating switch.
  • Two sets of auxiliary contacts may be fitted.

Complies with the standard

International Standards

IEC 60947-1 《Low-voltage switchgear and controlgear – Part 1: General》

IEC 60947-3 《Low-voltage switchgear and controlgear – Switches, isolators, isolating switches and fuses》

National Standards

GB/T 14048.1 《General Requirements for Low-Voltage Switchgear and Control Gear》

GB/T 14048.3 《Control Gear for Low-Voltage Switchgear, Low-Voltage Switches, Isolators, Isolating Switches and Fuse-Combined Units》

Key Technical Specifications

Rated current In(A) 63A 100A 160A 250A 630A 1600A 3150A
Conventional heating current Ith(A) 40 63 80 100 125 160 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150
Rated insulation voltage Ui(V) (Installation Categories IV) 690 690 690 690 690 750 1000
Dielectric strength (V) 1890 1890 2200 2200 2200 2200 2200
Rated impulse withstand voltage Uimp(kV) 8 8 8 8 8 8 12
Rated operating current le(A) AC-21B 40 63 80 100 125 160 200 250 315 400 500 630 1000 1250 1600 2000 2500 3150
AC-22B 40 63 80 100 125 160 200 250 315 400 500 630 / / / / / /
AC-23B 40 63 80 100 125 160 200 250 315 400 500 630 / / / / / /
Motor power P(kW) 400V 18.5 25 40 40 63 80 100 132 160 220 280 315 560 560 560 710 710 710
Rated short-time withstand current Icw(kA Rms) 1s 6 6 6 6 6 6 20 20 20 20 20 20 50 50 50 50 50 50
Rated breaking capacity Icn(A Rms) AC-23B 380V 320 504 640 800 1000 1080 1600 2000 2520 3200 4000 5040 1500 1875 2400 3000 3750 4725
Rated switching capacity Icm(A Rms) AC-23B 380V 400 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 1500 1875 2400 3000 3750 4725
Rated short-circuit making capacity Icm(kA Peak) 9.2 9.2 9.2 9.2 9.2 9.2 40 40 40 40 40 40 70 70 70 105 105 105
Mechanical life 400V 1700 1700 1700 1700 1400 1400 1400 1400 800 800 800 800 500 500 500 500 500 300
Electrical life 400V 300 300 300 300 200 200 200 200 200 200 200 200 100 100 100 100 100 100
Operating torque (N.m) 1.2 1.2 1.2 1.2 6.5 6.5 10 10 21 21 21 21 37 37 37 50 50 50
Weight (kg) 3 Pole 0.4 0.4 0.55 0.55 1.2 1.2 2 2 4.4 4.4 4.9 4.9 13.2 14.6 15.6 25.5 25.5 31
4 Pole 0.42 0.42 0.62 0.62 1.4 1.4 2.35 2.35 5.5 5.5 6.3 6.3 14.8 17.1 18 37.5 37.5 51.5

Operating Instructions

Direct operation: the handle is fitted directly in the centre of the switch

External operation: the handle is fitted on the outside of the switchboard door

Operating Instructions

HGL(ETGL)-63A~100A Load disconnector

63A-100A are suitable for switching circuits on and off or for electrical isolation

63A-100A are available in 3-pole and 4-pole versions (3-pole plus a switchable neutral pole)

HGL(ETGL)-63A~100A Load disconnector

HGL(ETGL)-160A-630A Operations inside the cabinet

HGL(ETGL)-160A-630A Operations inside the cabinet

HGL(ETGL)-160A-630A Operations from outside the cabinet

HGL(ETGL)-160A-630A Operations from outside the cabinet

Key Technical Specifications

Specifications Dimensions Installation dimensions
In A B C D D1 E ΦL F H N P R S U ΦX Y J K
125A/3 140 135 121 15 93 71 5.5 50 10 75 36 20 25 115 9 24 120 65
125A/4 170 135 121 15 93 71 5.5 50 10 75 36 20 25 115 9 24 150 65
160A/3 140 135 121 15 93 71 5.5 50 10 75 36 20 25 115 9 24 120 65
160A/4 170 135 121 15 93 71 5.5 50 10 75 36 20 25 115 9 24 150 65
200A/3 180 170 144 20 104 84 5.5 79 15 105 50 25 30 140 11 25 160 90
200A/4 230 170 144 20 104 84 5.5 79 15 105 50 25 30 140 11 25 210 90
250A/3 180 170 144 20 104 84 5.5 79 15 105 50 25 30 140 11 25 160 90
250A/4 230 170 144 20 104 84 5.5 79 15 105 50 25 30 140 11 25 210 90
315A/3 230 240 179 30 137 115 7 95 20 135 65 32 40 206 11 37 210 140
315A/4 290 240 179 30 137 115 7 95 20 135 65 32 40 206 11 37 270 140
400A/3 230 240 179 30 137 115 7 95 20 135 65 32 40 206 11 37 210 140
400A/4 290 240 179 30 137 115 7 95 20 135 65 32 40 206 11 37 270 140
500A/3 230 260 179 30 137 115 7 95 20 135 65 40 50 220 13 37.5 210 140
500A/4 290 260 179 30 137 115 7 95 20 135 65 40 50 220 13 37.5 270 140
630A/3 230 260 179 30 137 115 7 95 20 135 65 40 50 220 13 37.5 210 140
630A/4 290 260 179 30 137 115 7 95 20 135 65 40 50 220 13 37.5 270 140

Outline and installation Dimensions(mm)

HGL(ETGL)-63A Operations inside the cabinet

HGL(ETGL)-63A Operations inside the cabinet

HGL(ETGL)-100A Operations inside the cabinet

HGL(ETGL)-100A Operations inside the cabinet

HGL(ETGL)-1000~3150A 0utline and installation Dimensions

HGL(ETGL)-1000~3150A 0utline and installation Dimensions

Key Technical Specifications

Specifications Dimensions Installation dimensions
In A B N P R U V W X Y Y1 J K
1000A/3 378 308 174 120 60 200 35 20 16.5 49 353 175
1000A/4 493 310 235 120 60 200 35 20 16.5 48 471 174
1250A/3 378 336 174 120 80 200 40 35 16 49 353 175
1250A/4 493 338 235 120 80 200 40 35 16 48 471 174
1600A/3 378 336 174 120 80 200 40 35 16 50 353 175
1600A/4 493 338 235 120 80 200 40 35 16 49 471 174
2000A/3 378 445 174 120 80 200 40 40 20 103 208.5 353 220
2000A/4 493 447 235 120 80 200 40 40 20 104 210 471 220
2500A/3 378 445 174 120 80 200 40 40 20 103 208.5 353 220
2500A/4 493 447 235 120 80 200 40 40 20 104 210 471 220
3150A/3 378 492 174 120 120 200 50 50 21 77 237 353 220
3150A/4 493 494 235 120 120 200 50 50 21 78 238 471 220