HD11FA Series Anti-Misoperation Open-Type Knife Switch

The HD11FA open-type knife switch (anti-misoperation type) is suitable for rated insulation voltage 1000 V, rated operational voltage 690 V, and rated operational current from 200 A to 1500 A. It is mainly used in low-voltage complete sets of equipment for making and breaking circuits and isolating power supply under no-load conditions. The technical performance of this switch complies with IEC 60947-3 and GB/T 14048.3 standards.

Âmbito de Aplicação

The HD11FA open-type knife switch (anti-misoperation type) is suitable for rated insulation voltage 1000 V, rated operational voltage 690 V, and rated operational current from 200 A to 1500 A. It is mainly used in low-voltage complete sets of equipment for making and breaking circuits and isolating power supply under no-load conditions. The technical performance of this switch complies with IEC 60947-3 and GB/T 14048.3 standards.

Normal Service and Installation Conditions

  • Ambient air temperature not higher than +40 °C and not lower than -5°C.
  • Installation altitude not exceeding 2000 m.
  • Humidity: At a maximum temperature of +40 °C, the relative humidity of the air shall not exceed 50%. Higher relative humidity is permitted at lower temperatures (e.g., 90% at 20 °C). Appropriate measures shall be taken against occasional condensation caused by temperature variations.
  • Pollution degree of the surrounding environment is degree 3.
  • The switch shall be installed in a location free from significant vibration, shock vibration and rain/snow exposure. The installation site shall be free from explosive media, and the medium shall contain no gases or dust sufficient to corrode metal or damage insulation.

Model Designation DH11FA

Main Technical Parameters

200 400 600 1000 1500
Conventional free-air thermal current (A) 200 400 600 1000 1500
Rated operational voltage (V) 400/690 400/690 400/690 400/690 400/690
Tensão de isolamento nominal (V) 200 400 600 1000 1500
Rated operational current (A) 1000 1000 1000 1000 1000
Mechanical endurance (operations) 8000 5000 5000 3000 3000
1 s short-time withstand current (kA) 8 15 20 25 35
Operating force (N) ≤ 300 ≤ 400 ≤ 400 ≤ 450 ≤ 450

Outline and Mounting Dimensions (mm)

HD11FA-400/38 and Below
HD11FA-400 38 and Below

HD11FA-600/38 and Above
HD11FA-600 38 and Above

Baseplate Machining Mode: Compression Molded (Resin Plate, Glass Fiber Plate)

Modelo Dimensões gerais Mounting Dimensions
A B E F H J K O P M Φ C D
HD11FA-200/38 190 204 70 160 152 110 / / / 8 7 70 140
HD11FA-400/38 210 244 80 210 170 146 / / / 12 7 80 190
HD11FA-600/38 260 278 100 160 168 239 40 / / 16 9 100 140
HD11FA-1000/38 310 308 120 170 185 208 50 26 26 2-12 9 120 140
HD11FA-1500/38 340 335 130 170 210 228 70 35 35 4-12 9 130 140

Baseplate Machining Mode: Machined (Bakelite Plate, Epoxy Plate)

Modelo Dimensões gerais Mounting Dimensions
A B E F H J K O P M Φ C D
HD11 FA-200/38 192 210 70 160 152 110 / / / 8 7 70 140
HD11 FA-400/38 220 249 80 210 170 146 / / / 12 7 80 190
HD11 FA-600/38 270 278 100 160 168 239 40 / / 16 9 100 140
HD11 FA-1000/38 325 308 120 175 185 208 50 26 26 2-12 9 120 140
HD11 FA-1500/38 360 335 130 175 210 228 70 35 35 4-12 9 130 140

HD11FA/39
HD11FA-39(1)
HD11FA-39(2)

Baseplate Machining Mode: Machined (Bakelite Plate, Epoxy Plate)

Modelo Dimensões gerais Mounting Dimensions
A B E F H J I K O P M Φ C D
HD11FA-200/39 192 219 70 190 152 60 26 / / / 8 7 70 160
HD11FA-400/39 220 244 80 215 170 70 29 / / / 12 7 80 190
HD11FA-600/39 270 328 100 260 168 140 37 40 / / 16 9 100 220
HD11FA-1000/39 325 368 120 290 185 160 23 50 26 26 2-12 9 120 260
HD11FA-1500/39 360 420 130 340 210 180 23 70 35 35 4-12 9 130 300

Safety and Precautions

This series of open-type knife switches is strictly prohibited from load operation. During opening operation, the unlocking mechanism shall be set to the “Unlocked” position. After closing operation, check that the locking mechanism is in the “Locked” position.
The open-type knife switch may only be inspected or maintained when the circuit is completely disconnected from the power supply (i.e., in a de-energized condition).
After the open-type knife switch is put into service, periodic inspection and maintenance shall be carried out.
If you would like more information about the HD11FA knife switch, such as operating instructions, pricing, maintenance, and other related details, please contact us.

Avaliações

Ainda não há avaliações.

Seja o primeiro a avaliar “HD11FA Series Anti-Misoperation Open-Type Knife Switch”

O seu endereço de email não será publicado. Campos obrigatórios marcados com *