{"id":3044,"date":"2026-08-20T22:20:27","date_gmt":"2026-08-20T22:20:27","guid":{"rendered":"https:\/\/cnsuton.com\/?p=3044"},"modified":"2026-08-20T22:47:34","modified_gmt":"2026-08-20T22:47:34","slug":"type-3-surge-protector-guide-for-panel-builders","status":"publish","type":"post","link":"https:\/\/cnsuton.com\/pt\/blog\/type-3-surge-protector-guide-for-panel-builders\/","title":{"rendered":"Coloca\u00e7\u00e3o de Protetor contra Sobretens\u00e3o Tipo 3 Pr\u00f3ximo a Cargas Sens\u00edveis"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Protetor contra sobretens\u00f5es do Tipo 3<\/strong> A sele\u00e7\u00e3o coloca uma prote\u00e7\u00e3o residual fina junto ou perto de equipamento sens\u00edvel ap\u00f3s um andar Tipo 2 a montante. O dispositivo \u00e9 uma prote\u00e7\u00e3o residual de onda combinada \/ Classe III para entradas de equipamento, n\u00e3o um exerc\u00edcio de classifica\u00e7\u00e3o energ\u00e9tica de entrada de servi\u00e7o. As sec\u00e7\u00f5es abaixo abordam quando adicionar o Tipo 3, como este difere do servi\u00e7o residual do Tipo 2, que marca\u00e7\u00f5es Up\/Uc\/Uoc importam e como manter os condutores curtos na carga.<\/p>\n<figure style=\"float:none;clear:both;margin:28px auto;text-align:center;\"><img decoding=\"async\" src=\"images\/type-3-point-of-use-protection-map.webp\" alt=\"Type 3 point-of-use residual protection near sensitive equipment\" style=\"display:block;float:none;clear:both;width:100%;height:auto;margin:0 auto;;max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" loading=\"lazy\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">Conte\u00fado<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#what-a-type-3-surge-protector-does-at-the-equipment-side\">O que um Protetor de Sobretens\u00e3o do Tipo 3 Faz no Lado do Equipamento<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#why-type-3-must-supplement-type-2-protection\">Porque \u00e9 que a Prote\u00e7\u00e3o do Tipo 3 Deve Complementar a Prote\u00e7\u00e3o do Tipo 2<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#when-panel-builders-add-type-3-near-sensitive-loads\">Quando os Construtores de dormentes Adicionam o Tipo 3 Perto de Cargas Sens\u00edveis<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#type-2-versus-type-3-location-waveform-and-residual-duty\">Tipo 2 Versus Tipo 3: Localiza\u00e7\u00e3o, Forma de Onda e Carga Residual<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#select-up-uc-and-uoc-for-type-3-duty\">Selecione Up, Uc e Uoc para o regime Tipo 3<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#place-type-3-close-to-the-load-and-keep-leads-short\">Coloque o Tipo 3 Perto da Carga e Mantenha os Condutores Curtos<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#din-rail-hard-wired-and-plug-in-type-3-form-factors\">Fatores de forma Tipo 3 para calha DIN, cablagem fixa e liga\u00e7\u00e3o por ficha<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#confirm-type-class-marking-on-suton-modular-spd-paths\">Confirmar marca\u00e7\u00e3o de Tipo\/Classe nos caminhos do SPD Modular SUTON<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#faq\">FAQ<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"what-a-type-3-surge-protector-does-at-the-equipment-side\">O que um Protetor de Sobretens\u00e3o do Tipo 3 Faz no Lado do Equipamento<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Um protetor contra sobretens\u00f5es do Tipo 3 \u00e9 o andar residual de precis\u00e3o instalado junto de ou perto de cargas sens\u00edveis para limitar a sobretens\u00e3o transit\u00f3ria restante ap\u00f3s os andares de SPD a montante. Na linguagem da Classe III da IEC, \u00e9 caracterizado por uma onda combinada de ondas de tens\u00e3o (1,2\/50 \u03bcs) e de ondas de corrente (8\/20 \u03bcs), com o Uoc como um par\u00e2metro carater\u00edstico do Tipo 3.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os fabricantes de pain\u00e9is suprem esta necessidade em entradas de PLC, HMI, instrumenta\u00e7\u00e3o ou de comandos de m\u00e1quinas, onde a prote\u00e7\u00e3o ao n\u00edvel da placa, por si s\u00f3, deixa demasiado esfor\u00e7o residual nos terminais do equipamento. A quest\u00e3o n\u00e3o \u00e9 \u201cqual \u00e9 a intensidade da corrente de descargas atmosf\u00e9ricas na entrada de servi\u00e7o\u201d, mas sim \u201cqual \u00e9 a proximidade do limitador final em rela\u00e7\u00e3o \u00e0 carga vulner\u00e1vel\u201d.\u201d<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os profissionais descrevem frequentemente os dispositivos de Classe III \/ Tipo 3 como prote\u00e7\u00e3o do lado do equipamento, incluindo r\u00e9guas de tomadas com prote\u00e7\u00e3o contra sobretens\u00f5es utilizadas no equipamento a proteger. O tipo de montagem pode mudar; o papel residual permanece local.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os leitores que necessitam de separa\u00e7\u00e3o de fun\u00e7\u00f5es entre disjuntor e SPD podem utilizar o <a href=\"https:\/\/cnsuton.com\/pt\/blog\/circuit-breaker-surge-protector-guide-for-panel-builders\/\">Guia de disjuntores e protetores contra sobretens\u00e3o<\/a> sem transformar esta p\u00e1gina noutro artigo de taxonomia de dispositivos.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"why-type-3-must-supplement-type-2-protection\">Porque \u00e9 que a Prote\u00e7\u00e3o do Tipo 3 Deve Complementar a Prote\u00e7\u00e3o do Tipo 2<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os DPC do Tipo 3 t\u00eam uma baixa capacidade de descarga, pelo que devem ser instalados como um suplemento a um DPC do Tipo 2 e na proximidade de cargas sens\u00edveis. Tratar um m\u00f3dulo de tomadas ou um bloco do Tipo 3 para calha DIN como um sistema de gest\u00e3o de energia de sobretens\u00e3o para todo o edif\u00edcio deixa o andar de energia a montante por resolver.<\/p>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Importante:<\/strong> O <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/The_Surge_Protection_Device_(SPD)\" rel=\"nofollow noopener\" target=\"_blank\">Guia de Instala\u00e7\u00e3o El\u00e9trica: Tipologia de SPD<\/a> refere que os SPD do Tipo 3 devem ser obrigatoriamente instalados como um suplemento a um SPD do Tipo 2 perto de cargas sens\u00edveis devido \u00e0 sua baixa capacidade de descarga.<\/p>\n<\/blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\">A discuss\u00e3o no f\u00f3rum sobre protetores intermut\u00e1veis faz o mesmo ponto pr\u00e1tico: a ajuda dos dispositivos de classe D \/ estilo de liga\u00e7\u00e3o \u00e9 esperada ap\u00f3s a devida prote\u00e7\u00e3o a montante de classe B ou C, e n\u00e3o como um substituto para a mesma.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Um construtor de m\u00e1quinas que instala apenas m\u00f3dulos do Tipo 3 no lado do equipamento ainda precisa de uma fase do Tipo 2 definida no caminho de distribui\u00e7\u00e3o que alimenta esses arm\u00e1rios. A prote\u00e7\u00e3o diferencial local responde a uma quest\u00e3o diferente da gest\u00e3o de energia ao n\u00edvel do quadro.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"when-panel-builders-add-type-3-near-sensitive-loads\">Quando os Construtores de dormentes Adicionam o Tipo 3 Perto de Cargas Sens\u00edveis<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Adicione prote\u00e7\u00e3o fina do Tipo 3 perto de cargas sens\u00edveis quando a dist\u00e2ncia em rela\u00e7\u00e3o ao DPC da extremidade de entrada for grande ou quando a sensibilidade do equipamento exigir um andar residual final. A p\u00e1gina de elementos do Guia de Instala\u00e7\u00e3o El\u00e9trica enquadra prote\u00e7\u00e3o fina adicional quando as cargas est\u00e3o localizadas a mais de 10 metros de dist\u00e2ncia do dispositivo de prote\u00e7\u00e3o da extremidade de entrada.<\/p>\n<figure style=\"float:none;clear:both;margin:28px auto;text-align:center;\"><img decoding=\"async\" src=\"images\/type-3-when-to-add-decision.webp\" alt=\"When panel builders add Type 3 near sensitive loads\" style=\"display:block;float:none;clear:both;width:100%;height:auto;margin:0 auto;;max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" loading=\"lazy\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">A dist\u00e2ncia \u00e9 um acionamento pr\u00e1tico, n\u00e3o um substituto para a verifica\u00e7\u00e3o da suportabilidade do equipamento. Um alimentador curto ainda pode necessitar do Tipo 3 quando a carga \u00e9 excecionalmente sens\u00edvel, enquanto um alimentador longo quase sempre requer que o andar residual seja reconsiderado no quadro.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">As perguntas de coloca\u00e7\u00e3o \u00fateis incluem:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">O dispositivo protegido \u00e9 um PLC, uma HMI, uma alimenta\u00e7\u00e3o de instrumentos ou outra alimenta\u00e7\u00e3o de eletr\u00f3nica de baixa energia?<\/li>\n<li style=\"margin:0 0 8px\">A que dist\u00e2ncia \u00e9 essa carga do local do Tipo 2 a montante no diagrama unifilar?<\/li>\n<li style=\"margin:0 0 8px\">Ser\u00e1 que as cargas indutivas locais no circuito criam eventos que o DPA do quadro poder\u00e1 n\u00e3o tratar totalmente nos terminais do equipamento?<\/li>\n<li style=\"margin:0 0 8px\">O local do Tipo 3 ainda est\u00e1 coordenado com o mesmo conceito de liga\u00e7\u00e3o \u00e0 terra e equipotencializa\u00e7\u00e3o utilizado para o DPC a montante?<\/li>\n<\/ul>\n<p style=\"margin:0 0 16px;line-height:1.7\">As discuss\u00f5es nas comunidades sobre se o Tipo 2 j\u00e1 torna o Tipo 3 redundante normalmente ignoram as diferen\u00e7as de fixa\u00e7\u00e3o residual e o risco de um \u00fanico andar de prote\u00e7\u00e3o falhar ou deixar passar energia excessiva num quadro distante.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"type-2-versus-type-3-location-waveform-and-residual-duty\">Tipo 2 Versus Tipo 3: Localiza\u00e7\u00e3o, Forma de Onda e Carga Residual<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">O Tipo 2 gere a energia residual do quadro el\u00e9trico; o Tipo 3 conclui a prote\u00e7\u00e3o fina no lado do equipamento. Mantenha a sele\u00e7\u00e3o de corrente de descarga de rel\u00e2mpagos da entrada de servi\u00e7o do Tipo 1 fora desta decis\u00e3o, a menos que j\u00e1 esteja aberto um estudo separado para a entrada.<\/p>\n<figure style=\"float:none;clear:both;margin:28px auto;text-align:center;\"><img decoding=\"async\" src=\"images\/type-2-vs-type-3-decision-scan.webp\" alt=\"Type 2 versus Type 3 location and residual duty comparison\" style=\"display:block;float:none;clear:both;width:100%;height:auto;margin:0 auto;;max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" loading=\"lazy\" \/><\/figure>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"tabela de dados com deslocamento\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Decis\u00e3o<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Descarregador de \u26a1 Tipo 2 (SPD)<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">SPD do Tipo 3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Localiza\u00e7\u00e3o principal<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Quadro el\u00e9ctrico \/ subquadro<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">No equipamento sens\u00edvel ou perto dele<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Papel de prote\u00e7\u00e3o<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Est\u00e1gio de energia residual principal ap\u00f3s o conceito de entrada<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Est\u00e1gio de res\u00edduos finos \/ ponto de uso<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Enquadramento de formas de onda<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Frequentemente discutido com o termo de descarga 8\/20 \u00b5s<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Onda combinada 1,2\/50 \u03bcs + 8\/20 \u03bcs; caracter\u00edstica Uoc<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Marca\u00e7\u00e3o de foco para RFQs<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Conforme aplic\u00e1vel \/ Imax \/ Up \/ Uc<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tipo\/Classe, Uoc, Up, Uc<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Trabalho aut\u00f3nomo para a energia dos edif\u00edcios?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Est\u00e1gio residual ao n\u00edvel da placa<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Suplemento ao Tipo 2 perto da carga<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">Use esta tabela para evitar que a linguagem do Tipo 1 com forte teor de impulso (impulse-heavy) transborde para um RFQ residual do lado do equipamento. Se o comprador realmente precisar de capacidade de corrente de descargas atmosf\u00e9ricas na entrada de servi\u00e7o, trata-se de um artigo diferente e de um conjunto de marca\u00e7\u00f5es diferente.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">As perguntas sobre a disposi\u00e7\u00e3o de pain\u00e9is que misturam seccionadores de SPD e coordena\u00e7\u00e3o de disjuntores pertencem ao <a href=\"https:\/\/cnsuton.com\/pt\/blog\/surge-protector-breaker-guide-for-panel-builders\/\">guia de disjuntores com prote\u00e7\u00e3o contra sobretens\u00e3o<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"select-up-uc-and-uoc-for-type-3-duty\">Selecione Up, Uc e Uoc para o regime Tipo 3<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Escolha o n\u00edvel de prote\u00e7\u00e3o contra sobretens\u00e3o Up para que a tens\u00e3o residual se mantenha compat\u00edvel com a suportabilidade a sobretens\u00f5es do equipamento, defina o Uc para a tens\u00e3o cont\u00ednua do sistema e solicite a linguagem Uoc \/ Classe de Ensaio quando o servi\u00e7o for um andar residual de SPD de Classe III. As fichas de par\u00e2metros que apenas divulgam um valor comercial de tens\u00e3o residual sem essas vincula\u00e7\u00f5es est\u00e3o incompletas para a aceita\u00e7\u00e3o do quadro.<\/p>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"tabela de dados com deslocamento\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Marca\u00e7\u00e3o<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">O que \u00e9 que responde<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Pergunta de sele\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Para cima<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">N\u00edvel de prote\u00e7\u00e3o contra tens\u00e3o residual sob condi\u00e7\u00f5es de surto definidas<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">O equipamento Up below withstand \u00e9 utilizado nesta alimenta\u00e7\u00e3o?<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">UC<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tens\u00e3o m\u00e1xima de funcionamento cont\u00ednuo que o SPD pode suportar<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ser\u00e1 que a Uc cobre a tens\u00e3o real do sistema e o esquema de liga\u00e7\u00e3o \u00e0 terra?<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Uoc \/ Type Class<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Linguagem de carateriza\u00e7\u00e3o do Tipo 3 \/ Classe III<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">A marca\u00e7\u00e3o identifica o servi\u00e7o residual do Tipo 3 \/ Classe III em vez de outra fase?<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Forma \/ polos \/ modos<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Como o SPD se liga no circuito<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Os polos e os modos de prote\u00e7\u00e3o correspondem ao sistema de alimenta\u00e7\u00e3o na entrada do equipamento?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">A norma IEC 61643-11 abrange os requisitos de produto e os m\u00e9todos de ensaio para OsD conectados a sistemas de energia de baixa tens\u00e3o, enquanto a IEC 61643-12 abrange os princ\u00edpios de sele\u00e7\u00e3o, aplica\u00e7\u00e3o e coordena\u00e7\u00e3o. Os documentos do projeto continuam a determinar a suportabilidade exata do equipamento e a tens\u00e3o do sistema utilizadas para a aceita\u00e7\u00e3o.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os utilizadores em f\u00f3runs de profissionais desconfiam frequentemente do marketing baseado no valor da garantia e exigem, em vez disso, clareza quanto ao tipo\/classe. Indique o Tipo\/Classe e Uoc\/Up\/Uc no pedido de cota\u00e7\u00e3o (RFQ) antes de debater slogans de marcas.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"place-type-3-close-to-the-load-and-keep-leads-short\">Coloque o Tipo 3 Perto da Carga e Mantenha os Condutores Curtos<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Monte o dispositivo do Tipo 3 junto ou perto do equipamento protegido e mantenha o comprimento dos condutores curto para que a tens\u00e3o residual de aperto n\u00e3o seja enfraquecida por deriva\u00e7\u00f5es indutivas longas. As regras de cablagem do Guia de Instala\u00e7\u00e3o El\u00e9trica enfatizam um caminho de liga\u00e7\u00e3o curto do DPS entre a rede (atrav\u00e9s do SCPD externo) e o bloco de terminais de terra, com um limite pr\u00e1tico de 50 cm para esse comprimento de liga\u00e7\u00e3o.<\/p>\n<figure style=\"float:none;clear:both;margin:28px auto;text-align:center;\"><img decoding=\"async\" src=\"images\/type-3-placement-lead-length.webp\" alt=\"Type 3 placement near equipment with short connection leads\" style=\"display:block;float:none;clear:both;width:100%;height:auto;margin:0 auto;;max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" loading=\"lazy\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Um m\u00f3dulo Tipo 3 em calha DIN instalado na extremidade de um longo percurso de cabo pode parecer arrumado no esquema, mas anula a raz\u00e3o pela qual foi adicionado. Mantenha os alimentadores protegidos separados dos desprotegidos onde as regras de instala\u00e7\u00e3o o exigirem, e reduza os loops desnecess\u00e1rios no caminho de liga\u00e7\u00e3o do DPS.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A linguagem de campo das discuss\u00f5es do EEVblog \u00e9 direta: evite \"stubs\" (deriva\u00e7\u00f5es) por causa da indut\u00e2ncia do fio do \"stub\". Esse aviso deve constar junto \u00e0 decis\u00e3o de montagem, e n\u00e3o numa nota de rodap\u00e9 de comissionamento posterior.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"din-rail-hard-wired-and-plug-in-type-3-form-factors\">Fatores de forma Tipo 3 para calha DIN, cablagem fixa e liga\u00e7\u00e3o por ficha<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">M\u00f3dulos para calha DIN, dispositivos de ponto de utiliza\u00e7\u00e3o cablados diretamente e r\u00e9guas de tomadas podem todos desempenhar um papel residual de Classe III quando as marca\u00e7\u00f5es e a coordena\u00e7\u00e3o a montante correspondem \u00e0 fun\u00e7\u00e3o. O formato altera o acondicionamento da instala\u00e7\u00e3o; n\u00e3o anula a regra do suplemento do Tipo 2.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Escolha m\u00f3dulos do tipo 3 em calha DIN quando o arm\u00e1rio de equipamento j\u00e1 utiliza dispositivos de prote\u00e7\u00e3o modulares e necessita de uma instala\u00e7\u00e3o fixa documentada. Escolha dispositivos de ponto de utiliza\u00e7\u00e3o cablados quando a alimenta\u00e7\u00e3o protegida for uma entrada de m\u00e1quina dedicada e n\u00e3o uma tomada. Trate as r\u00e9guas de tomadas de ligar como ferramentas residuais do lado do equipamento apenas quando as respetivas marca\u00e7\u00f5es de Tipo\/Classe e a prote\u00e7\u00e3o a montante forem expl\u00edcitas.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A mesma decis\u00e3o residual pode, portanto, aparecer em tr\u00eas pacotes mec\u00e2nicos. Pe\u00e7a primeiro a marca\u00e7\u00e3o e, em seguida, escolha o pacote que se adequa ao arm\u00e1rio e \u00e0 pr\u00e1tica de manuten\u00e7\u00e3o.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"confirm-type-class-marking-on-suton-modular-spd-paths\">Confirmar marca\u00e7\u00e3o de Tipo\/Classe nos caminhos do SPD Modular SUTON<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Utilize a documenta\u00e7\u00e3o de descarregadores de sobretens\u00e3o (SPD) modulares de calha DIN da SUTON como ponto de partida para a identidade da fam\u00edlia, confirme depois a marca\u00e7\u00e3o de Tipo\/Classe antes de tratar qualquer refer\u00eancia (SKU) como sendo de Tipo 3. O p\u00fablico <a href=\"https:\/\/cnsuton.com\/pt\/produto\/etu1-series-surge-protective-device\/\">Dispositivo de Prote\u00e7\u00e3o contra Sobretens\u00f5es da S\u00e9rie ETU1<\/a> a p\u00e1gina descreve uma fam\u00edlia de DPC modulares de interior para sistemas de baixa tens\u00e3o de corrente alternada, incluindo polos publicados, exemplos de Uc, valores de Up inferiores a 2,5 kV na tabela ETU1 publicada e tempo de resposta inferior a 25 ns.<\/p>\n<figure style=\"float:none;clear:both;margin:28px auto;text-align:center;\"><img decoding=\"async\" src=\"images\/etu1-modular-spd-type-class-silhouette.webp\" alt=\"SUTON ETU1 modular SPD documentation path silhouette\" style=\"display:block;float:none;clear:both;width:100%;height:auto;margin:0 auto;;max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" loading=\"lazy\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Esses factos familiares publicados sustentam uma conversa de documenta\u00e7\u00e3o. N\u00e3o provam, por si s\u00f3, uma marca\u00e7\u00e3o Tipo 3 \/ Classe III para cada linha da p\u00e1gina, e as linhas Iimp (10\/350 \u00b5s) publicadas n\u00e3o devem ser copiadas para um RFQ residual de Tipo 3 como se fossem classifica\u00e7\u00f5es de Tipo 3.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Come\u00e7ar a partir de <a href=\"https:\/\/cnsuton.com\/pt\/modular-din-rail-products\/\">Produtos modulares para calha DIN<\/a> hub quando o leitor necessita do caminho mais abrangente para dispositivos de prote\u00e7\u00e3o modulares. Se for necess\u00e1ria clarifica\u00e7\u00e3o da documenta\u00e7\u00e3o atual para uma marca\u00e7\u00e3o espec\u00edfica de Tipo\/Classe, utilize <a href=\"https:\/\/cnsuton.com\/pt\/contact-us\/\">contacto<\/a> apenas para essa quest\u00e3o de documenta\u00e7\u00e3o; n\u00e3o encare o contacto como uma promessa de MOQ, prazo de entrega, garantia ou aprova\u00e7\u00e3o de projeto.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"faq\">FAQ<\/h2>\n<h3 style=\"margin:28px 0 12px\">O que \u00e9 um protetor contra sobretens\u00e3o do Tipo 3?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u00c9 o andar de SPD residual fino\/de ponto de utiliza\u00e7\u00e3o perto de equipamento sens\u00edvel, caracterizado por ensaios de onda combinada (tens\u00e3o de 1,2\/50 \u03bcs e corrente de 8\/20 \u03bcs) e utilizado ap\u00f3s andares de prote\u00e7\u00e3o a montante.<\/p>\n<h3 style=\"margin:28px 0 12px\">Pode um SPD de Tipo 3 substituir um SPD de Tipo 2?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">N\u00e3o. O Tipo 3 tem baixa capacidade de descarga e deve ser instalado como um suplemento ao Tipo 2 perto de cargas sens\u00edveis.<\/p>\n<h3 style=\"margin:28px 0 12px\">Quando \u00e9 que devo adicionar um SPD do Tipo 3 se j\u00e1 tiver um SPD no quadro el\u00e9trico?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Adicione um SPD do Tipo 3 quando as cargas sens\u00edveis estiverem afastadas do SPD a montante \u2014 a mais de 10 m da protec\u00e7\u00e3o na extremidade de entrada, na pr\u00e1tica do Guia de Instala\u00e7\u00e3o El\u00e9ctrica \u2014 ou quando a sensibilidade do equipamento ainda necessitar de um est\u00e1gio residual final no quadro.<\/p>\n<h3 style=\"margin:28px 0 12px\">Que marca\u00e7\u00f5es devem constar num RFQ do Tipo 3?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Identifica\u00e7\u00e3o do tipo\/classe, Uoc onde aplic\u00e1vel, Up referenciado \u00e0 suportabilidade do equipamento e Uc adaptado \u00e0 tens\u00e3o do sistema. N\u00e3o substitua a linguagem de Iimp do Tipo 1 pela corrente residual do Tipo 3.<\/p>\n<h3 style=\"margin:28px 0 12px\">Onde deve o Tipo 3 ser montado numa m\u00e1quina ou num subpainel?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Monte-o na entrada do equipamento protegido ou pr\u00f3ximo dela \u2014 PLC\/HMI\/instrumento ou alimenta\u00e7\u00e3o da m\u00e1quina \u2014 para que o grampo residual fique local \u00e0 carga sens\u00edvel.<\/p>\n<h3 style=\"margin:28px 0 12px\">Qu\u00e3o curtos devem ser os terminais do Tipo 3?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Mantenha os cabos de liga\u00e7\u00e3o do DPS curtos. A pr\u00e1tica de cablagem do Guia de Instala\u00e7\u00e3o El\u00e9trica limita o caminho de liga\u00e7\u00e3o da rede do DPS ao terminal de terra a cerca de 50 cm e alerta contra deriva\u00e7\u00f5es longas que adicionam indut\u00e2ncia.<\/p>\n<h3 style=\"margin:28px 0 12px\">Ser\u00e1 que uma r\u00e9gua de tomadas \u00e9 o mesmo que um m\u00f3dulo de Tipo 3 para calha DIN?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">N\u00e3o mecanicamente. Ambos podem desempenhar um papel residual de Classe III quando a sinaliza\u00e7\u00e3o e a coordena\u00e7\u00e3o a montante est\u00e3o correctas, mas os blocos para calha DIN e os blocos com cablagem fixa adaptam-se de forma diferente a instala\u00e7\u00f5es em arm\u00e1rios fixos, em compara\u00e7\u00e3o com as r\u00e9guas de tomadas de ligar.<\/p>\n<h3 style=\"margin:28px 0 12px\">A SUTON publica um SKU com a marca\u00e7\u00e3o Tipo 3 na p\u00e1gina ETU1?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">A p\u00e1gina p\u00fablica ETU1 publica dados da fam\u00edlia de descarregadores de sobretens\u00e3o modulares. Confirme a marca\u00e7\u00e3o de Tipo\/Classe em rela\u00e7\u00e3o \u00e0 documenta\u00e7\u00e3o atual antes de tratar qualquer SKU como sendo de servi\u00e7o Tipo 3 \/ Classe III.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">Refer\u00eancias<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/5682\" rel=\"nofollow noopener\" target=\"_blank\">Requisitos e m\u00e9todos de ensaio para protectores contra sobretens\u00f5es de baixa tens\u00e3o IEC<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32531\" rel=\"nofollow noopener\" target=\"_blank\">Princ\u00edpios de sele\u00e7\u00e3o e aplica\u00e7\u00e3o de SPD segundo a IEC<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.eevblog.com\/forum\/beginners\/how-protect-high-voltage-coming-from-ground-using-spd\/\" rel=\"nofollow noopener\" target=\"_blank\">EEVblog: Prote\u00e7\u00e3o do Tipo 3\/C no equipamento e indut\u00e2ncia de deriva\u00e7\u00e3o<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.eevblog.com\/forum\/chat\/differences-in-ac-mains-surge-protection\/\" rel=\"nofollow noopener\" target=\"_blank\">EEVblog: Diferen\u00e7as na prote\u00e7\u00e3o contra picos de tens\u00e3o na rede el\u00e9trica<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Selecione um protetor contra sobretens\u00f5es do tipo 3 para prote\u00e7\u00e3o residual no lado do equipamento: coordena\u00e7\u00e3o do tipo 2, marca\u00e7\u00f5es Up\/Uc\/Uoc, dist\u00e2ncia de coloca\u00e7\u00e3o e verifica\u00e7\u00f5es de RFQ em calha DIN.<\/p>","protected":false},"author":3,"featured_media":3039,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-3044","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts\/3044","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/comments?post=3044"}],"version-history":[{"count":1,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts\/3044\/revisions"}],"predecessor-version":[{"id":3061,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts\/3044\/revisions\/3061"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/media\/3039"}],"wp:attachment":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/media?parent=3044"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/categories?post=3044"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/tags?post=3044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}