{"id":2838,"date":"2026-08-01T01:00:00","date_gmt":"2026-08-01T01:00:00","guid":{"rendered":"https:\/\/cnsuton.com\/?p=2838"},"modified":"2026-08-01T01:00:00","modified_gmt":"2026-08-01T01:00:00","slug":"100-amp-breaker-guide-for-panel-builders","status":"publish","type":"post","link":"https:\/\/cnsuton.com\/pt\/blog\/100-amp-breaker-guide-for-panel-builders\/","title":{"rendered":"Guia de Disuntores de 100 Amperes para Eletricistas e Montadores de Quadros"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>A 100 amperes, o disjuntor \u00e9 infraestrutura: o calibre, as regula\u00e7\u00f5es, a seletividade e a interface de alimenta\u00e7\u00e3o decidem a ordem \u2014 a corrente nominal \u00e9 a parte mais f\u00e1cil.<\/strong><\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Modular range top-end context for the 100 amp frame boundary\" src=\"https:\/\/cnsuton.com\/wp-content\/uploads\/2026\/07\/ETC65-125-Series.3.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\">Conte\u00fado<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-which-duty-class-does-100-amps-serve\">Parte 1. A que classe de servi\u00e7o serve 100 amperes?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-where-is-the-mcb-and-mccb-boundary-at-100-amps\">Parte 2. Onde \u00e9 que se situa o limite entre o MCB e o MCCB aos 100 amperes?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-how-is-the-conductor-coordinated-with-the-breaker\">Parte 3. Como \u00e9 que o condutor \u00e9 coordenado com o disjuntor?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-what-settings-does-the-protection-duty-need\">Parte 4. De que defini\u00e7\u00f5es precisa a fun\u00e7\u00e3o de prote\u00e7\u00e3o?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-how-are-selectivity-and-source-arrangements-planned\">Parte 5. Como s\u00e3o planeadas a seletividade e as disposi\u00e7\u00f5es das fontes?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-what-belongs-in-the-rfq-and-fit-boundary\">Parte 6. O que pertence ao RFQ e ao Limite de Adequa\u00e7\u00e3o?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-7-where-can-suton-product-routes-fit\">Parte 7. Onde se podem encaixar as rotas de produtos SUTON?<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-1-which-duty-class-does-100-amps-serve\">Parte 1. A que classe de servi\u00e7o serve 100 amperes?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Cem amperes marcam o dever da infraestrutura: o dispositivo principal de um pequeno quadro, ou uma posi\u00e7\u00e3o de alimentador num maior. De qualquer forma, o dispositivo encontra-se agora entre a alimenta\u00e7\u00e3o e tudo o que est\u00e1 a jusante, pelo que o seu modo de falha, o acesso para manuten\u00e7\u00e3o e a documenta\u00e7\u00e3o seguem a disciplina de entrada. A fun\u00e7\u00e3o de isolamento que acompanha uma posi\u00e7\u00e3o principal \u00e9 abordada no <a href=\"https:\/\/cnsuton.com\/pt\/blog\/main-switch-selection-for-lv-distribution-panels\/\">guia de sele\u00e7\u00e3o do interruptor geral<\/a>, e o contexto do quadro no <a href=\"https:\/\/cnsuton.com\/pt\/blog\/circuit-breaker-panel-guide-for-panel-builders\/\">guia do quadro el\u00e9trico<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-2-where-is-the-mcb-and-mccb-boundary-at-100-amps\">Parte 2. Onde \u00e9 que se situa o limite entre o MCB e o MCCB aos 100 amperes?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Esta classifica\u00e7\u00e3o situa-se no topo de muitas escalas modulares e na base das gamas de caixa moldada, pelo que ambas as fam\u00edlias aparecem entre aspas.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Fator de decis\u00e3o<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Gama alta modular<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Disjuntor compacto (MCCB)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Capacidade de corte vs estudo de curto-circuito<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">n\u00edveis de defeito moderados<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">maior capacidade de interrup\u00e7\u00e3o dispon\u00edvel<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Defini\u00e7\u00f5es de prote\u00e7\u00e3o<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">carater\u00edsticas fixas<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">op\u00e7\u00f5es ajust\u00e1veis em muitas arma\u00e7\u00f5es<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Formato f\u00edsico<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">calha DIN, larguras modulares<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">montagem do quadro, n\u00f3s de uni\u00e3o, espa\u00e7adores<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Acess\u00f3rios e sinaliza\u00e7\u00e3o<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">verbos auxiliares b\u00e1sicos<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">ecossistema de viagens e sinaliza\u00e7\u00e3o mais rico<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Capacidade futura no quadro<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">no topo do escadote<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">quarto da fam\u00edlia Frame<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os fundamentos de caixas moldadas residem no <a href=\"https:\/\/cnsuton.com\/pt\/blog\/mccb-breaker-guide-for-panel-builders-and-contractors\/\">Guia de disjuntores MCCB<\/a>. Registe a decis\u00e3o da estrutura e o respetivo motivo no cronograma; a esta classifica\u00e7\u00e3o \u201cqualquer um\u201d n\u00e3o serve de resposta.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-3-how-is-the-conductor-coordinated-with-the-breaker\">Parte 3. Como \u00e9 que o condutor \u00e9 coordenado com o disjuntor?<\/h2>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Derating factor review for infrastructure-duty conductor coordination\" src=\"https:\/\/cnsuton.com\/wp-content\/uploads\/2026\/07\/DERATING-FACTOR.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">O dimensionamento de condutores a 100 A \u00e9 um c\u00e1lculo de projeto sujeito \u00e0s regras de instala\u00e7\u00e3o aplic\u00e1veis \u2014 o m\u00e9todo, a temperatura ambiente, o agrupamento, a constru\u00e7\u00e3o do cabo, o comprimento do trajeto e as quest\u00f5es relativas a condutores em paralelo interferem todos, n\u00e3o sendo aqui citada nenhuma tabela de sec\u00e7\u00f5es como regra universal. As infraestruturas adicionam as suas pr\u00f3prias verifica\u00e7\u00f5es: a queda de tens\u00e3o ao longo do alimentador, o desempenho da malha de defeito na extremidade distante e os limites de temperatura de termina\u00e7\u00e3o no dispositivo.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os terminais merecem aten\u00e7\u00e3o expl\u00edcita neste momento. O tipo de terminal, a prepara\u00e7\u00e3o do condutor e os valores de bin\u00e1rio constam da documenta\u00e7\u00e3o do dispositivo, e o registo do bin\u00e1rio pertence ao processo de comissionamento.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-4-what-settings-does-the-protection-duty-need\">Parte 4. De que defini\u00e7\u00f5es precisa a fun\u00e7\u00e3o de prote\u00e7\u00e3o?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Muitas caixas moldadas com esta corrente nominal oferecem regula\u00e7\u00f5es ajust\u00e1veis de sobrecarga e curto-circuito; algumas acrescentam disparadores eletr\u00f3nicos com medi\u00e7\u00e3o e comunica\u00e7\u00e3o, tal como a fam\u00edlia de medi\u00e7\u00e3o inteligente da SUTON. As regula\u00e7\u00f5es s\u00e3o resultados de projeto e n\u00e3o prefer\u00eancias do instalador \u2014 o estudo de prote\u00e7\u00e3o fixa-as, o registo de comissionamento comprova-as e qualquer altera\u00e7\u00e3o posterior constitui um evento controlado.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Caso o dispositivo tamb\u00e9m sirva para medi\u00e7\u00e3o ou monitoriza\u00e7\u00e3o, defina a interface de dados numa fase precoce: o que \u00e9 medido, para onde reporta e quem \u00e9 o propriet\u00e1rio da configura\u00e7\u00e3o. Adicionar comunica\u00e7\u00f5es a um alimentador de entrada ap\u00f3s a energiza\u00e7\u00e3o \u00e9 muito mais dif\u00edcil do que especific\u00e1-las no pedido de cota\u00e7\u00e3o (RFQ).<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-5-how-are-selectivity-and-source-arrangements-planned\">Parte 5. Como s\u00e3o planeadas a seletividade e as disposi\u00e7\u00f5es das fontes?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Um dispositivo de infraestrutura deve permitir que os dispositivos a jusante eliminem as suas pr\u00f3prias avarias. A seletividade face aos subcircuitos \u2014 e face \u00e0 prote\u00e7\u00e3o a montante \u2014 \u00e9 demonstrada com dados de coordena\u00e7\u00e3o do fabricante aos n\u00edveis de avaria calculados, arquivados no dossier do quadro.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Os arranjos de fontes complicam o panorama: a seguran\u00e7a por gerador, os esquemas de transfer\u00eancia ou as alimenta\u00e7\u00f5es em paralelo alteram os n\u00edveis de defeito e as sequ\u00eancias de comuta\u00e7\u00e3o na entrada. Onde quer que qualquer um destes exista, o dispositivo de 100 A \u00e9 selecionado dentro desse esquema, e n\u00e3o isoladamente, e a l\u00f3gica de transfer\u00eancia \u00e9 revista como um sistema.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-6-what-belongs-in-the-rfq-and-fit-boundary\">Parte 6. O que pertence ao RFQ e ao Limite de Adequa\u00e7\u00e3o?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Ordeze a posi\u00e7\u00e3o, n\u00e3o o n\u00famero.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Campo RFQ<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Porque \u00e9 que isso importa<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Servi\u00e7o: entrada ou alimentador, com o diagrama unifilar<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">corrige a fun\u00e7\u00e3o e a disciplina<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Estudo de alimenta\u00e7\u00e3o e faltas<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">repara o quadro e o dever de quebra<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Enquadrar a decis\u00e3o com o motorista<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">fam\u00edlia de produtos fixa<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Defini\u00e7\u00f5es e requisitos da unidade de disparo<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">corre\u00e7\u00f5es do comportamento de prote\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tratamento de fases e neutro<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">corre\u00e7\u00f5es de disposi\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Expectativas de seletividade<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">exige provas de coordena\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Necessidades de contagem e comunica\u00e7\u00e3o<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">corre\u00e7\u00f5es de interfaces<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Montagem, terminais, normas, quantidade<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">corre\u00e7\u00f5es no \u00e2mbito da assemblia<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Ajustar Limite:<\/strong> Este guia estrutura 100 dados de entrada para a sele\u00e7\u00e3o de infraestruturas A. N\u00e3o realiza estudos de defeitos nem de prote\u00e7\u00e3o, n\u00e3o cita as regras de servi\u00e7o de nenhuma jurisdi\u00e7\u00e3o e n\u00e3o pode planear a substitui\u00e7\u00e3o de uma entrada \u2014 o isolamento do lado da alimenta\u00e7\u00e3o e a coordena\u00e7\u00e3o com a distribuidora s\u00e3o eventos de engenharia espec\u00edficos de cada local. Resolva primeiro essas quest\u00f5es com a entidade respons\u00e1vel pelo projeto e com as partes encarregues.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-7-where-can-suton-product-routes-fit\">Parte 7. Onde se podem encaixar as rotas de produtos SUTON?<\/h2>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Molded case residual breaker class illustrating the MCCB family\" src=\"https:\/\/cnsuton.com\/wp-content\/uploads\/2026\/06\/ETM3EL-Series-Electronic-Residual-Current-Circuit-Breaker1.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Para um ponto de partida de recomenda\u00e7\u00e3o de produtos nesta fun\u00e7\u00e3o, reveja o de SUTON <a href=\"https:\/\/cnsuton.com\/pt\/produto\/etm1-series-molded-case-circuit-breaker\/\">disjuntor em caixa moldada da s\u00e9rie ETM1<\/a> percurso para posi\u00e7\u00f5es de alimenta\u00e7\u00e3o e principais, e o <a href=\"https:\/\/cnsuton.com\/pt\/produto\/etm3e-series-intelligent-measurement-circuit-breaker\/\">disjuntor inteligente de medi\u00e7\u00e3o da s\u00e9rie ETM3E<\/a> trajeto em que a medi\u00e7\u00e3o e a comunica\u00e7\u00e3o pertencem ao mesmo quadro. Os quadros, os intervalos de parametriza\u00e7\u00e3o e os dados de interrup\u00e7\u00e3o s\u00e3o espec\u00edficos do modelo \u2014 confirme as fichas t\u00e9cnicas em rela\u00e7\u00e3o ao estudo de defeito, e depois envie o diagrama unifilar <a href=\"https:\/\/cnsuton.com\/pt\/contact-us\/\">Contactar SUTON<\/a> para uma revis\u00e3o documentada.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\">Disciplina de entrada na pr\u00e1tica<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Planeie a interrup\u00e7\u00e3o antes da encomenda. A substitui\u00e7\u00e3o de um interruptor geral requer isolamento do lado da alimenta\u00e7\u00e3o, um procedimento confirmado de trabalhos sem tens\u00e3o e um plano de ensaio de reenergiza\u00e7\u00e3o; o dispositivo \u00e9 frequentemente a linha mais barata desse projeto. As compras devem ver o plano log\u00edstico junto com a cota\u00e7\u00e3o, porque as datas de entrega determinam as janelas de interrup\u00e7\u00e3o.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Mantenha as defini\u00e7\u00f5es de prote\u00e7\u00e3o sob controlo de altera\u00e7\u00f5es. Uma folha de defini\u00e7\u00f5es assinada na coloca\u00e7\u00e3o em servi\u00e7o, uma c\u00f3pia no dossier do painel e uma regra de que ningu\u00e9m ajusta uma unidade de disparo sem uma folha revista \u2014 esse \u00e9 todo o sistema e evita o desvio cl\u00e1ssico em que os ajustes no terreno comprometem silenciosamente o estudo de seletividade.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Por fim, reveja o estudo de faltas quando a rede sofrer altera\u00e7\u00f5es. Um novo transformador, um gerador ou um motor de grande porte a montante podem alterar a capacidade de corte na entrada; o dispositivo de 100 A que era adequado na fase de projeto deve ser novamente verificado face aos novos valores, recorrendo a registos e n\u00e3o \u00e0 mem\u00f3ria.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\">FAQ<\/h2>\n<h3 style=\"margin:28px 0 12px\">Para que serve um disjuntor de 100 amperes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fun\u00e7\u00e3o de infraestrutura: o dispositivo principal de um pequeno quadro de distribui\u00e7\u00e3o ou de uma posi\u00e7\u00e3o de chegada num maior, selecionado com a disciplina de cabe\u00e7a de s\u00e9rie.<\/p>\n<h3 style=\"margin:28px 0 12px\">Que calibre de fio \u00e9 necess\u00e1rio para um disjuntor de 100 amperes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Esse \u00e9 um c\u00e1lculo de projeto de acordo com as regras de instala\u00e7\u00e3o aplic\u00e1veis \u2014 o m\u00e9todo, a temperatura ambiente, o agrupamento, a constru\u00e7\u00e3o do cabo, o comprimento e os limites de termina\u00e7\u00e3o participam todos; n\u00e3o se aplica nenhuma tabela universal.<\/p>\n<h3 style=\"margin:28px 0 12px\">Um disjuntor de 100 amperes \u00e9 um MCB ou um MCCB?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Ambas as fam\u00edlias existem a esta classifica\u00e7\u00e3o ou perto dela; o estudo de defeitos, as necessidades de parametriza\u00e7\u00e3o e o contexto de montagem decidem o tamanho, e o cronograma deve registar o acionador.<\/p>\n<h3 style=\"margin:28px 0 12px\">Como \u00e9 tratada a seletividade em redor de um disjuntor de 100 amperes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Com os dados de coordena\u00e7\u00e3o do fabricante nos n\u00edveis de defeito calculados, demonstrados perante os dispositivos a jusante e a prote\u00e7\u00e3o a montante, e arquivados no dossier do quadro.<\/p>\n<h3 style=\"margin:28px 0 12px\">Que regula\u00e7\u00f5es pode ter um disjuntor de caixa moldada de 100 amperes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Consoante o calibre: regula\u00e7\u00f5es ajust\u00e1veis de sobrecarga e de curto-circuito, e nas unidades de disparo eletr\u00f3nicas, op\u00e7\u00f5es de medi\u00e7\u00e3o e de comunica\u00e7\u00e3o \u2014 tudo definido pelo estudo de prote\u00e7\u00e3o.<\/p>\n<h3 style=\"margin:28px 0 12px\">Quais os dados que devem constar num pedido de cota\u00e7\u00e3o (RFQ) para um disjuntor de 100 amperes?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fornecer o dever e o diagrama unifilar, dados de alimenta\u00e7\u00e3o e de falta, decis\u00e3o de tamanho, necessidades de ajustes e da unidade de disparo, polos, expectativas de seletividade, interfaces de medi\u00e7\u00e3o, montagem, normas e quantidade.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\">Refer\u00eancias<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/6012\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60947-2 \u2014 Disjuntores<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/21972\" rel=\"nofollow noopener\" target=\"_blank\">IEC 60898-1 \u2014 Disuntores para prote\u00e7\u00e3o contra sobrecorrentes<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/6734\" rel=\"nofollow noopener\" target=\"_blank\">IEC 61439-1 \u2014 Conjuntos de aparelhagem de baixa tens\u00e3o<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/electronics.howstuffworks.com\/circuit-breaker.htm\" rel=\"nofollow noopener\" target=\"_blank\">HowStuffWorks \u2014 Como funcionam os disjuntores<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>At 100 amperes the breaker is infrastructure: frame, settings, selectivity, and the supply interface decide the order \u2014 the rating is the easy part. Contents Part 1. Which duty class does 100 amps serve? Part 2. Where is the MCB and MCCB boundary at 100 amps? Part 3. How is the conductor coordinated with the [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2793,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2838","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"_links":{"self":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts\/2838","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/comments?post=2838"}],"version-history":[{"count":1,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts\/2838\/revisions"}],"predecessor-version":[{"id":2915,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/posts\/2838\/revisions\/2915"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/media\/2793"}],"wp:attachment":[{"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/media?parent=2838"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/categories?post=2838"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnsuton.com\/pt\/wp-json\/wp\/v2\/tags?post=2838"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}